В наличии
4104504/10 | 2227K WTRL RG6 QD 1000
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +125 °C (-40 °F to +257 °F) |
Product Type
|
Coaxial video cable |
Jacket Material
|
PVDF |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Packaging Type
|
Reel |
Cable weight
|
44.645 kg/km | 30 lb/kft |
Jacket Color
|
White |
Cable Type
|
Series 6 |
Environmental Space
|
Plenum |
Portfolio
|
CommScope® |
Safety Standard
|
ETL | cETL |
Capacitance
|
50.853 pF/m | 15.5 pF/ft |
Cable Length
|
304.8 m | 1000 ft |
Construction Type
|
Non-armored |
Product Number
|
2227K |
Nominal Velocity of Propagation (NVP)
|
84 % |
Flame Test Method
|
CMP |
Center Conductor Gauge
|
18 AWG |
Supported Application
|
Video |
Diameter Over Dielectric
|
4.318 mm | 0.17 in |
Diameter Over Jacket, nominal
|
6.604 mm | 0.26 in |
Jacket Thickness
|
0.406 mm | 0.016 in |
Conductor dc Resistance
|
93.832 ohms/km | 28.6 ohms/kft |
Dielectric Material
|
Foam FEP |
Outer Shield (Braid) Coverage
|
40 % |
Outer Shield (Braid) Material
|
Aluminum |
Outer Shield (Tape) Material
|
Aluminum/Poly, non-bonded |
Diameter Over Center Conductor Tolerance
|
±0.0004 in |
Diameter Over Jacket Tolerance
|
±0.004 in |
Diameter Over Outer Shield (Braid)
|
5.893 mm | 0.232 in |
Characteristic Impedance
|
75 ohm |
Characteristic Impedance Tolerance
|
±3 ohm |
Jacket Spark Test Voltage
|
2500 Vac |
Shield dc Resistance
|
17.388 ohms/km | 5.3 ohms/kft |
1.0 MHz
|
1.250 |
10.0 MHz
|
2.300 |
100.0 MHz
|
6.590 |
1000.0 MHz
|
24.440 |
Center Conductor Material
|
Copper-clad steel wire |
50.0 MHz
|
4.850 |
200.0 MHz
|
9.380 |
Inner Shield (Braid) Coverage
|
60 % |
Minimum Bend Radius, loaded, times
|
20 times |
400.0 MHz
|
13.870 |
700.0 MHz
|
19.550 |
900.0 MHz
|
22.830 |
1200.0 MHz
|
27.060 |
1800.0 MHz
|
35.060 |
Minimum Bend Radius, unloaded, times
|
10 times |
2500.0 MHz
|
38.380 |
3000.0 MHz
|
42.870 |
Center Conductor Type
|
Solid |
Inner Shield (Braid) Gauge
|
34 AWG |
2200.0 MHz
|
37.850 |
Inner Shield (Braid) Material
|
Aluminum |
Inner Shield (Tape) Material
|
Aluminum/Poly, bonded |
Structural Return Loss
|
15 dB @ 1000–3000 MHz | 20 dB @ 5–1000 MHz |
Outer Shield (Braid) Gauge
|
34 AWG |
Temperature Rating, UL
|
125 °C | 257 °F |
Structural Return Loss Test Method
|
100% Swept Tested |
Diameter Over Center Conductor, specific
|
0.0403 in per 1 strand |
Jacket Thickness, minimum spot
|
0.33 mm | 0.013 in |
Dielectric Strength, conductor to shield
|
2500 Vdc |
1450.0 MHz
|
30.640 |
Diameter Over Inner Shield (Braid)
|
5.131 mm | 0.202 in |