В наличии
8213304/10 | 5740R BKRL RG6 QD 1000
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +75 °C (-40 °F to +167 °F) |
Product Type
|
Coaxial satellite cable |
Jacket Material
|
PVC |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Packaging Type
|
Reel |
Cable weight
|
50.598 kg/km | 34 lb/kft |
Jacket Color
|
Black |
Cable Type
|
Series 6 |
Environmental Space
|
Non-plenum |
Portfolio
|
CommScope® |
Safety Standard
|
ETL | cETL |
Capacitance
|
52.493 pF/m | 16 pF/ft |
Cable Length
|
304.8 m | 1000 ft |
Construction Type
|
Non-armored |
Product Number
|
5740R |
Nominal Velocity of Propagation (NVP)
|
82 % |
Flame Test Method
|
CMR |
Center Conductor Gauge
|
18 AWG |
Diameter Over Dielectric
|
4.572 mm | 0.18 in |
Diameter Over Jacket, nominal
|
7.62 mm | 0.3 in |
Jacket Thickness
|
0.864 mm | 0.034 in |
Conductor dc Resistance
|
93.832 ohms/km | 28.6 ohms/kft |
Dielectric Material
|
Foam PE |
Outer Shield (Braid) Coverage
|
40 % |
Outer Shield (Braid) Material
|
Aluminum |
Outer Shield (Tape) Material
|
Aluminum/Poly, non-bonded |
Diameter Over Dielectric Tolerance
|
±0.004 in |
Diameter Over Jacket Tolerance
|
±0.008 in |
Diameter Over Outer Shield (Braid)
|
5.893 mm | 0.232 in |
Characteristic Impedance
|
75 ohm |
Characteristic Impedance Tolerance
|
±3 ohm |
Jacket Spark Test Voltage
|
2500 Vac |
Shield dc Resistance
|
16.076 ohms/km | 4.9 ohms/kft |
100.0 MHz
|
6.300 |
1000.0 MHz
|
20.040 |
Center Conductor Material
|
Copper-clad steel wire |
50.0 MHz
|
4.620 |
200.0 MHz
|
8.660 |
Inner Shield (Braid) Coverage
|
60 % |
Minimum Bend Radius, loaded, times
|
20 times |
400.0 MHz
|
12.230 |
700.0 MHz
|
16.560 |
900.0 MHz
|
18.990 |
1200.0 MHz
|
22.070 |
1800.0 MHz
|
27.650 |
Minimum Bend Radius, unloaded, times
|
10 times |
2500.0 MHz
|
32.700 |
3000.0 MHz
|
35.820 |
Center Conductor Type
|
Solid |
Inner Shield (Braid) Gauge
|
34 AWG |
5.0 MHz
|
2.032 |
55.0 MHz
|
4.825 |
2200.0 MHz
|
30.670 |
Inner Shield (Braid) Material
|
Aluminum |
Inner Shield (Tape) Material
|
Aluminum/Poly, bonded |
Structural Return Loss
|
15 dB @ 1000–3000 MHz | 20 dB @ 5–1000 MHz |
Outer Shield (Braid) Gauge
|
34 AWG |
Temperature Rating, UL
|
75 °C | 167 °F |
Structural Return Loss Test Method
|
100% Swept Tested |
Diameter Over Center Conductor, specific
|
0.0403 in per 1 strand |
Dielectric Strength, conductor to shield
|
2500 Vdc |
1450.0 MHz
|
24.570 |
Diameter Over Inner Shield (Braid)
|
5.385 mm | 0.212 in |